H3/5 GREEN (+) STARTER INPUT (KEY SIDE OF THE STARTER KILL)
H3/6
RED IGNITION 1 +12V INPUT (30A FUSED)
H3/7
PINK/WHITE (30) FLEX RELAY OUTPUT (car side of ign, acc or starter wire)
H3/8
PINK/BLACK (87a) FLEX RELAY INPUT (key side of ign, acc or starter wire if needed)
H3/9
RED/BLACK ACCESSORY/STARTER RELAY +12V INPUT (30A FUSED)
H3/10 NC No Connection
Door Lock, 3-pin connector
1 BLUE (-) 500mA UNLOCK OUTPUT
2 EMPTY NOT USED
3 GREEN (-) 500mA LOCK OUTPUT
Adjusting the Sensor
Important! Make sure the keypad is unlocked and the vehicle is disarmed with no open zones. The on board
shock sensor can be adjusted using the HD remote.
Adjusting the sensor:
Disarm1. the system, turn the ignition Off and close all the doors.
To enter Sensor Adjust, 2. press in and hold the menu wheel (for 3 seconds) on the remote control while
the display is blank. When the
Settings
screen appears, toggle the menu wheel up or down to the
Adjustments
screen and then press in on the menu wheel to enter.
In the 3.
Adjustments
menu, highlight
Sensor Adjust
and press the Menu Wheel. The remote requests the
current setting from the system and displays it in the
Sensor Adjustment
screen.
Follow the on screen instructions to change the setting in the display.4.
Toggle5. the menu wheel up/down or press the
/
A U X
buttons to change level.
When you have reached the desired level, 6. press and hold the menu wheel, the remote sends the level
setting in the display to the system; a long beep confirms the new level is set. To reset the level to factory
default, press the
A U X
button.
Note: You can test the new setting by cautiously impacting the vehicle with increasing intensity until the
siren chirps, indicating the impact level required to fully trigger the alarm.
Press7. the
A U X
button to exit and return to the
Adjustments
menu. The setting retains the last saved.
To exit the shock sensor adjustment mode from the control module:
Open an entry point or turn on the ignition, the control module emits one long chirp exiting adjustment
mode.
During level setting and level testing if more than 30 seconds lapses without any action the system will exit
sensor adjust and return to the Adjustment menu.
Adjusting the sensor with the 1way remote:
Disarm the system, turn the ignition Off and close all the doors.1.
Press and hold the 2.
A U X
button of the remote control for 8 seconds (If Car 2 mode is on, ignore the Car
Select beep after 3 seconds) or until the amber LED turns on.
Press and hold the 3.
A U X
button 1.5 seconds or until the amber led flashes then comes on solid.- The control
module emits one long chirp, confirming that it has entered adjustment mode.
Press the 4.
A U X
,
A U X
or
A U X
buttons to adjust the sensor level.
Note: You can test the new setting by cautiously impacting the vehicle with increasing intensity until the
siren chirps, indicating the impact level required to fully trigger the alarm.
•
A U X
button: Pressing this button increases the sensitivity one level. The siren chirps twice confirming the
sensitivity adjustment.
•
A U X
button: Pressing this button decreases the sensitivity one level. The siren chirps once confirming the
sensitivity adjustment.
10A FUSE
MINI ATM
RPN: 8540
LIGHT FLASH POLARITY
(10A (MAXIMUM) FUSE JUMPER)
+ -
09
11
10
06
08
07
22
66
88
77
1
1
1
1
0
1
1
1
1
0
99
55
1
2
1
2
44
33
ELECTRONICS
R
3
1
4
2
TACH LEARN THREASHOLD
JMP1 OFF ON
CPU1
NOTE: Pin 1 is on the left
TACH threshold OFF:
TACH threshold ON:
Bitwriter
Port
Neutral Safety
Switch
Remote
Start In
Status
LED
Valet
Port
Door Lock/
Unlock Output
Relay Out
Port
H2
Port
1
10 9 8 7 6
12345
1
1 8
51
1 3
10
12
To change
jumper
settings
1 12
Page view 6
1 2 3 4 5 6 7 8 9 10 11 12 ... 22 23

Comments to this Manuals

No comments