2-Setting Up the
Controller Area
Dual Flow %
You can set the tolerance between the flow switch monitor and the flow readings for
injection applications before the flow switch alarm activates due to out of tolerance
conditions.
Out of tolerance conditions must be met for at least five seconds before the alarms are
activated.
For Gran 3 applications, set the tolerances between the dual encoder readings before
the ‘Dual Flow’ alarm is enabled. The out of tolerance condition must be met for 5
seconds before the alarm occurs.
Off Rate %
You can set the Off Rate Percent alarm to activate when the actual application rate
differs from the application target rate for more than five seconds.
Low Tank
You can set the Low Tank alarm to activate when the tank falls below a designated
level. The alarm shuts off when either the booms are turned off or when you enter a
new value that is equal to or less than the current Tank Volume. If you enter a value of
zero in the field, the alarm is disabled.
Low Limit
You can set the Low Limit alarm to activate when the actual volume per minute rate
falls below the target rate. When the volume falls below the low limit rate, the control
valve stops closing and the alarm displays. This value automatically proportions to the
percentage of the booms that are in the ‘On’ position. For example, if this value is set
to four and half of the total boom length is on, Viper automatically sets the valve to two.