16
Optional Sensor Harness, 4-pinConnector
The four-pin sensor harness is optional, and is not included with this unit.
RED (+) 12V Constant and BLACK (-) Ground
These wires supply constant (+) 12 volts and ground to the optional sensor.
BLUE/GREEN (-) Multiplex Input
These wires are multiplex inputs. If a (-) input of less than 0.8 seconds is
supplied to either wire, the Warn-Away response will occur. A (-) input of
longer than 0.8 seconds to either wire will initiate the triggered sequence and
report Zone 4.
Programming Jumper
Light Flash Jumper
This jumper is used to determine the light flash output. In the (+) position,
the on-board relay is enabled and the unit will output (+)12V on the WHITE
wire, H1/2. In the (-) position, the on-board relay is disabled. The WHITE
wire, H1/2, will supply a 200 mA (-) output suitable for driving factory
parking light relays.